Datacenter

Your systems in the heart of Germany’s internet infrastructure

Locations

The services can be offered in four Frankfurt data centers. You choose the location that fits your requirements, as all locations are connected to each other redundantly.

MainNTT FRA1Eschborner Landstraße 100Werkhaus FRA4Kruppstraße 105Digital Realty FRA1 - FRA18Hanauer Landstraße 295Equinix FRA5Kleyerstraße 90

Werkhaus

The Werkhaus has room for up to 1,000 racks, which corresponds to around 16,000 servers. Power, cooling and security are redundant throughout, so your systems keep running even during faults. Operation uses green power.

up to 1,000
Racks
approx. 16,000
Servers
N+1
Air conditioning
24/7
Access and monitoring

Access and monitoring

  • Access around the clock
  • Controlled access to all rooms
  • Fingerprint readers as biometric access control
  • Intrusion alarm system
  • Video surveillance throughout the data center
  • Building monitoring around the clock

Fire protection

  • Fire compartments with F90 walls and steel security doors
  • Early fire detection via aspirating smoke detection (ASD/VESDA)
  • Automatic alerting of the fire department
  • Extinguishing with argon, which displaces oxygen and smothers the fire
  • Pressure relief and silencers for gas extinguishing

Power supply

  • Surge protection and regulated power distribution
  • Separate sub-distributions
  • Two standby power systems
  • Powerful emergency generator

Cooling and ventilation

  • Air conditioning units in an N+1 configuration
  • Cold air via the raised floor, exhaust air extracted at the ceiling
  • Separate cold and hot aisles
  • Controllable precision air conditioning
  • Direct and indirect free cooling

Digital Realty Frankfurt

Digital Realty operates more than twenty independent, interconnected data centers in Frankfurt. Frankfurt is home to DE-CIX and one of the most important internet exchange points in the world.

over 20
Data centers in Frankfurt
over 700
Carriers, NSPs, IX providers and ISPs
24/7
Staff on the campus
ISO 27001
and PCI DSS certified

Connectivity

  • Access to over 700 carriers, NSPs, IX providers and ISPs
  • Metro Connect links (managed wave and dark fiber) to all other Digital Realty data centers in Frankfurt

Security and fire protection

  • Security fence around the entire campus, equipped with modern alarm and surveillance technology
  • Own security and technical staff on site around the clock
  • Modern early fire detection and extinguishing technology

Certifications

  • ISO 27001 (information security)
  • ISO 22301 (business continuity)
  • ISO 9001 (quality management)
  • ISO 14001 (environmental management)
  • ISO 50001 (energy management)
  • PCI DSS

Energy efficiency

  • Modular design with highly efficient components
  • Building technology designed for low energy consumption

Equinix Frankfurt FR5

The FR5 IBX data center offers direct, settlement-free IP connectivity for important banking, trading and telecommunications infrastructure in Germany.

approx. 7,260 m²
Colocation floor space
N+1
UPS redundancy
N+1
Cooling redundancy
ISO 27001
and SOC 2 Type II certified

Power and cooling

  • Uninterruptible power supply with N+1 redundancy
  • Cooling with N+1 redundancy
  • Globally guaranteed availability of over 99.999%

Fire protection

  • Early fire detection via aspirating smoke detection (HSSD/VESDA) plus smoke detectors in ducts and at the ceiling
  • Double-interlock pre-action fire suppression system

Building and location

  • Around 78,100 ft² (approx. 7,260 m²) of floor space
  • Located above the 500-year flood level
  • Limited on-site parking

Certifications

  • ISO 27001 (information security)
  • ISO 9001 (quality management)
  • ISO 45001 (occupational health and safety)
  • ISO 50001 (energy management)
  • PCI DSS
  • SOC 1 Type II and SOC 2 Type II

NTT Frankfurt FR1

Frankfurt 1 is a carrier- and cloud-neutral data center operated by NTT. Power and cooling are designed independently and redundantly for each building.

110 kV
Feed from two substations
2N
UPS per building
99.999%
Power supply availability (SLA)
ISO 27001
based on IT-Grundschutz (BSI)

Power supply

  • 110 kV feed from two substations via two supply lines
  • Own substation with three 110/20 kV transformers in N+1
  • Separate UPS systems (A and B feed) with 2N redundancy per building
  • Emergency power via diesel generators in N+1
  • Average power density of 1 to 3 kW/m²

Connectivity

  • Carrier- and cloud-neutral
  • Redundant carrier access rooms in every building
  • Redundant meet-me rooms
  • Mix of global Tier-1 carriers and connection to DE-CIX
  • Options for connecting to the global NTT network

Climate

  • Redundantly designed cooling for every building
  • Climate conditions in line with ASHRAE guidelines

Certifications

  • EN 50600 (buildings E, F/G and H)
  • ISO 9001 (quality management)
  • ISO 50001 (energy management)
  • ISO 27001 based on IT-Grundschutz (BSI)
  • ISAE 3402 Type II
  • PCI DSS

Which location suits you?

Talk to us, we will advise you on locations and connectivity.

Contact us